The inlet length of a venturimeter is
WebThe inlet section of the Venturimeter is of the same diameter as that of the pipeline in which the venturimeter is installed. The second part is the Cylindrical Throat It is the middle part … WebApr 12, 2024 · A venturi meter is a device that is used to measure the speed flow of incompressible fluid through a pipe. The device converts pressure energy into kinetic …
The inlet length of a venturimeter is
Did you know?
WebThe inlet length of Venturimeter a) Is equal to outlet length b) Is more than outlet length c) Is less than outlet length d) None of the above WebThe flow through the venturimeter and hence through the pipe is given by. where. Q actual = Actual discharge in m 3 /s. C v =Discharge co-efficient of a venturimeter. A1 =area at the inlet side in m 2. A2 =area at the throat side in m 2. h =Differential pressure head of liquid in m. g =Acceleration due to gravity (9.81 m/s 2)
A venturimeter consists of four parts: 1. Cylindrical Inlet Section 2. Conical convergent Section 3. Cylindrical throat and 4. Conical divergent outlet Fig. 1 below shows a typical venturimeter diagram with its parts. There are two tappings on the venturi meter for pressure measurement; the upstream pressure … See more When a fluid flows through a venturimeter, it accelerates in the convergent section and then decelerates in the divergent section. The pressure difference between an upstream section and the throat is measured by a … See more Bernoulli’s principle states the relation between pressure (P), kinetic energy, and gravitational potential energy of a fluid inside a pipe. The mathematical form of Bernoulli’s equation is … See more Venturimeters find wide application in fluid industries. The major application of venturimeters include 1. Used in Engine Carburetors (Automobile Sector) to measure airflow 2. Used in process industries (Process … See more Normally three types of venturimeters are available: 1. Horizontal Venturimeter:This type of venturimeter has the highest kinetic energy and the lowest potential energy. 2. Vertical … See more WebThe length is equal to the diameter of the throat. Generally, the diameter of the throat is 1/4 to 3/4 of the diameter of the inlet pipe. Diverging cone: The diverging section has an angle 5 to 15 degree. The diverging angle is less than the converging angle.
WebQuestion #151055. a horizontal venturimeter with inlet diameter 30 cm and throat diameter 15cm is used to measure the flow of oil of specific gravity 0.8. The discharge of oil through venturimeter is 50 litres/s. Take C=0.98. write the reading of the oil-mercury differential manometer (x) Expert's answer. WebThe inlet length of Venturimeter a) Is equal to outlet length b) Is more than outlet length c) Is less than outlet length d) None of the above Facebook Email or phone
WebA Venturimeter is introduced in a 300 mm diameter horizontal pipeline carrying water undera pressure of 150 kN/m2. The throat diameter of the meter is 100 mm and the pressure at the throat is 400 mm of mercury below atmosphere. If 3% of the differential pressure is lost between the inlet and outlet throat, determine the flow rate in the pipe. peach dsWebThe classical venturi has a very long flow element characterized by a tapered inlet and a diverging outlet. This is an introduction guide to venturi meters. text.skipToContent text.skipToNavigation. Call us at 1-888-826-6342. ... These proprietary flow tubes usually cost less than the classical and short-form venturis because of their short lay ... peach dump cake recipe with yellow cake mixWebMar 4, 2024 · Abstract and Figures Venturi meter is a device which is used for measuring the rate of flow of fluid flowing through the pipes. The applications of these are found in various fields like Water... sdy hair colorWebApr 13, 2024 · Throat: It is the middle part of the venturi meter and has the lowest cross-sectional area. The length is equal to the diameter of the throat. Generally, the diameter of … peach dump cakes using cake mixWebA horizontal Venturimeter with inlet and throat diameters 300 mm and 100 mm respectively is used to measure the flow of water. The pressure intensity at inlet is 130 KN/m2, while the vacuum pressure head at the throat is 350 mm of mercury. Assuming that 3% of head is lost in between the inlet and throat, find, the value of Cd for the ... peach dump cake recipe using frozen peachesWebApr 8, 2024 · For most venturi flow meters, a straight pipe length of at least 10 diameters upstream of the meter and 5 diameters downstream of the meter is recommended to ensure an accurate flow measurement. However, the actual length required may vary depending on factors such as the flow rate, fluid viscosity, Reynolds number, and pipe roughness. sdy csgo statsWebNov 15, 2024 · The converging angle is 20-22 degrees, and the length of the converging area is about 2.7 Dd. Where D is the diameter of the inlet main and d is the diameter of the … sdyea